Skip to product information
1 of 3

PH and EC Eco Briefcase

PH and EC Eco Briefcase

Regular price €80,00 EUR
Regular price Sale price €80,00 EUR
Sale Sold out
Taxes included. Shipping calculated at checkout.

General shipping information

SHIPPING :

Orders are generally shipped within 24/48 business hours with a shipping agency.

*Orders DO NOT go out on Fridays to avoid them being stuck all weekend at the transport agency.

You can check the status of your order by sending us an email to firemouthaquaristic@gmail.com

Shipping price:

SPAIN PENINSULA:

- NACEX 24/48H - €5.95 | FREE ON ORDERS + €60

- NACEX SHIPPING LIVE ANIMAL 24H €15 | FREE ON ORDERS +150€

- NACEX HEAVY DELIVERY - €9 | €15 depending on product

- PICKUP FROM WAREHOUSE (ONLY FOR ALICANTE) - €0

ISLANDS, CEUTA AND MELILLA

We use the Correos parcel service with a flat rate of €22

However, write to us and tell us what you are interested in because if it is a smaller package, the costs will be much cheaper.

You only pay the exact Post Office rate

Write to us if you have questions

EUROPE / EUROPE

We use the Correos parcel service with a flat rate of €45

However, write to us and tell us what you are interested in because if it is a smaller package, the costs will be much cheaper.

We use the parcel service of Correos with a flat rate of € 45

However, write us and tell us what you are interested in because if it is a smaller package, the costs are much cheaper.

Fish Shipping Information ONLY

**Only valid for Spain PENINSULA

Shipping fish costs €15 (or free from €150.00) and is sent via urgent NACEX , delivering the package before 7pm.

You can also choose to pick it up at the agency first thing in the morning on
day delivery is scheduled, in this case, please write to us once the order has been placed at 664373985.

Once the package arrives you will have one hour to acclimatize and resolve any incidents.
of the animal, if it is not done in this way the right to claim the animals will be lost.

If you want to find a greater variety of fish, you can request to join the WhatsApp offers group where we will share a super large list of fish in which you will find a great variety of fish for very attractive prices.

The PH and EC PH600 and CD611 case brings together two Milwaukee meters in one protective and carrying case.

This PH and EC PH600 and CD611 case is ideal for Agriculture, hydroponics, marine aquariums, water treatment.

At your request we can change the PH and EC PH600 and CD611 case meters for other basic meters: example: CD601.

For your PH and EC PH600 and CD611 case meters to give you greater satisfaction and long life, you will need to take care of them.

For the PH600, a light brushing with a toothbrush every week will be enough, and every month with a bath in a sachet of cleaning liquid (M10016).

The PH600 meter has a scale from 0.0 to 14.0, Resolution of 0.1pH; manual one-point calibration (with screwdriver), 3 x 1.5V button cell.

The CD611 (EC) meter has a scale from 0.0 to 20.0 mS, resolution 0.1 mS, manual one-point calibration (with screwdriver), 3 x 1.5V button cell.

Operation : PH600

  • Don't be surprised to see white crystals surrounding the head of the meter. This is normal for a pH electrode. These salts will dissolve with water.
  • Remove the black protection and turn on the meter.
  • Submerge it to the limit and wait for the data to stabilize.
  • After use, rinse the electrode with water to keep it clean.
  • Preserve the electrode by putting a few drops of MA9015 storage liquid or pH 7.0 calibration liquid on the cap.
  • Always replace the lid after use.
  • DO NOT USE distilled or deionized water for storage.
  • Large reading differences (≈0.5 pH) may be due to need for calibration, dry electrode or low batteries

PH600 Calibration

  • The calibration procedure is simple and fast
  • Immerse up to the limit in pH 7.01 calibration liquid (M10007)

Wait for the data to stabilize and adjust to pH 7.0 with the screwdriver to the screw on the back.

  • The meter is calibrated.

ALWAYS USE fresh calibration fluids, and never use them again

Operation : CD611

Remove the black protection and turn on the meter with the ON/OFF button located above.

  • Submerge it to the limit and wait for the data to stabilize.
  • The meter automatically compensates for temperature variations.
  • After use, rinse the electrode with water to keep it clean.
  • The data communicated by the screen must be multiplied by 100 to give a direct reading in mS/cm.

CD611 Calibration

  • The calibration procedure is simple and fast
  • Immerse the meter up to the limit in EC calibration liquid (M10031)

Wait for the data to stabilize and with the screwdriver to the screw on the back,

set to 1.4 (multiplied by 100 gives an EC of 1413). The meter is calibrated.

ALWAYS USE fresh calibration fluids, and never reuse them.

For any questions regarding your PH and EC PH600 and CD611 briefcase, you can contact us. We will be happy to help you.

View full details

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)