Skip to product information
1 of 2

EC Controller: MC311

EC Controller: MC311

Regular price €160,00 EUR
Regular price Sale price €160,00 EUR
Sale Sold out
Taxes included. Shipping calculated at checkout.

General shipping information

SHIPPING :

Orders are generally shipped within 24/48 business hours with a shipping agency.

*Orders DO NOT go out on Fridays to avoid them being stuck all weekend at the transport agency.

You can check the status of your order by sending us an email to firemouthaquaristic@gmail.com

Shipping price:

SPAIN PENINSULA:

- NACEX 24/48H - €5.95 | FREE ON ORDERS + €60

- NACEX SHIPPING LIVE ANIMAL 24H €15 | FREE ON ORDERS +150€

- NACEX HEAVY DELIVERY - €9 | €15 depending on product

- PICKUP FROM WAREHOUSE (ONLY FOR ALICANTE) - €0

ISLANDS, CEUTA AND MELILLA

We use the Correos parcel service with a flat rate of €22

However, write to us and tell us what you are interested in because if it is a smaller package, the costs will be much cheaper.

You only pay the exact Post Office rate

Write to us if you have questions

EUROPE / EUROPE

We use the Correos parcel service with a flat rate of €45

However, write to us and tell us what you are interested in because if it is a smaller package, the costs will be much cheaper.

We use the parcel service of Correos with a flat rate of € 45

However, write us and tell us what you are interested in because if it is a smaller package, the costs are much cheaper.

Fish Shipping Information ONLY

**Only valid for Spain PENINSULA

Shipping fish costs €15 (or free from €150.00) and is sent via urgent NACEX , delivering the package before 7pm.

You can also choose to pick it up at the agency first thing in the morning on
day delivery is scheduled, in this case, please write to us once the order has been placed at 664373985.

Once the package arrives you will have one hour to acclimatize and resolve any incidents.
of the animal, if it is not done in this way the right to claim the animals will be lost.

If you want to find a greater variety of fish, you can request to join the WhatsApp offers group where we will share a super large list of fish in which you will find a great variety of fish for very attractive prices.

The EC controller MC311 is a continuous EC (Electro Conductivity) controller meter in mS (millisiemens) with visual alarm and 220V coupling plug for external electrical equipment: a dosing pump for example.

This external equipment will be activated when the controlling meter has passed the set point (set with the graduated wheel) and will inject solution (e.g. nutrients) into the tank.

MC311 EC controller is ideal for agriculture, hydroponics.

The MC311 EC controller has a scale of 0.0 up to 10.0 mS. It has automatic temperature compensation.

Its calibration is manual (calibration nut with screwdriver).

Its control block has a wheel to set the setpoint data with two fingers: from 0.8 to 2.8 mS.

At the same time that the outdoor equipment is activated, a visual alarm (red LED) will also be activated. Calibration of the MC311 EC controller is manual (in 1 points: use 1413uS or 5000 uS buffer).

The MC311 EC controller is supplied with its MA812/2 probe with a 2-meter cable, a 12 VDC adapter, an EC1413uS calibration envelope, and a manual in Spanish.

Installation and measurement:

Connect the 12VDC transformer to the power

Connect the coupling plug to the power supply (white and black socket)

Connect the external equipment (dosing pump) to the coupling socket (white part).

Make sure the meter was calibrated before use.

Immerse the EC electrode in the tank (let it float with the help of a wide polystyrene for example).

Or if you prefer to measure in pipe, request a threaded probe holder from your supplier.

Turn on the meter by pressing the ON/OFF button

Place the Right Button in the BELOW position to activate the pump when the EC drops below the set point.

Calibration: Immerse the electrode in a sachet of EC1413uS calibration liquid.

With the help of a screwdriver, adjust the data to 1.4 (they are the first two digits of 1413).

The meter is calibrated and ready to measure and activates the external equipment.

It is advisable to calibrate the meter at least once every two months, or after a long period of non-use.